Sewer connection

The slot units »Pfuhler-Schlitzrinnen-System Z« are connected to the drainage sewers and pipes by installing appropriate drainage manholes for the system. They can be supplied with design and material to match the requirements and delivered with concreted in socket or coupler or with glued on PE-HD coupler. The connections can be installed vertically downwards or horizontally in the side. Depending on the use, a pipe for connection to the channel system is to be designed in accordance with TRwS 7861 »Construction of sealed surfaces«, Section 8, TRwS 7812 »Petrol stations for motor vehicles«, Section 5.4.2, TRwS 7823 »Refuelling of rail vehicles«, Section 5.3.2 and TRwS 7844 »Refuelling aircraft«, Section 5.4.2. The pipe and its connection affects the usability of the channel system for backwater or for exclusively backwater free discharge of water polluting liquids. The distances between the connections must be adjusted to the size of the respective catchment/runoff area.

Example Manhole Type N

Example Manhole Type K

1 »Technische Regeln wassergefährdender Stoffe: Ausführung von Dichtflächen«; DWA-A 786; DWA Deutsche Vereinigung für Wasserwirtschaft und Abfall e.V. Hennef; Oktober 2005

2 »Technische Regeln wassergefährdender Stoffe: Tankstellen für Kraftfahrzeuge«; ATV-DVWK-A 781; DWA Deutsche Vereinigung für Wasserwirtschaft und Abfall e.V. Hennef; August 2004

3 »Technische Regeln wassergefährdender Stoffe: Betankung von Schienenfahrzeugen«; DWA-A 782; DWA Deutsche Vereinigung für Wasserwirtschaft und Abfall e.V. Hennef; Mai 2006

4 »Technische Regeln wassergefährdender Stoffe: Betankung von Luftfahrzeugen«; DWA-A 784; DWA Deutsche Vereinigung für Wasserwirtschaft und Abfall e.V. Hennef; April 2006